Large Buildings 2012 BCIN Exam Free Assessment

Enter your email address* and click on Next to start your quiz!

 

*Your email will not be sold, shared or used with the exception of Orderline sending you additional information on study aids and courses available to assist in your educational and career goals.

Which of the following buildings is required to comply with Part 3 of Division B?
a) a church with an occupant load of 250 persons
b) a two storey hotel with a building area of 500 m²
c) a 3 storey office building with a building area of 590 m²
d) a 2 storey retail store with a building area of 600 m²
In a six storey combustible residential building, what is the required fire resistance rating of a fire separation between the residential occupancy and a restaurant with an occupant load of 56 persons?
a) 2 hrs
b) 1hr
c) 45 min.
d) 1 1/2 hours
In a six storey combustible building constructed in accordance with Article 3.2.2.43A. is the exterior cladding on the building permitted to be combustible?
a) Yes since the building is combustible
b) No because the building is more than 4 storeys high
c) No because the building cannot be constructed as a combustible building
d) none of the above
What is the maximum size of a combustible skylight in a building required to be of noncombustible construction?
a) 27 m2 with a flame spread rating of 150
b) 27 m2 with a flame spread rating of 75
c) 9 m2 with a flame spread rating of 75
d) b) and c)
Which of the following buildings required to be of noncombustible construction are permitted to have exterior non-loadbearing wall assemblies that includes combustible components?
a) a 7 storey sprinklered building
b) a 5 storey non-sprinklered building
c) a 4 storey sprinklered building
d) a 5 storey non-sprinklerted building
Clause 3.1.5.5.(1)(a) permits combustible components in an exterior wall assembly in a building required to be of noncombustible construction provided the building not more than 3 storeys in height or not more than 6 storeys in height if sprinklered.
a) 20 m2
b) not more than 30% of the floor area of the live/work unit
c) not more than 25% of the floor area of the live/work
d) a) and c)
If a door opening in a fire separation with a 2 hour fire resistance rating is protected with two doors in the opening what fire protection rating would each door have to have?
a) ¾ hour
b) 1 ½ hours
c) 1 hour
d) none of the above
When can the temperature rise limits on a door between an exit enclosure a corridor be waived?
a) when the corridor is separated from the remainder of the floor area by a fire separation with a fire resistance rating of not more than 1 hour
b) when the corridor is separated from the remainder of the floor area by a fire separation with a fire resistance rating of not more than 1.5 hours
c) when the corridor is separated from the remainder of the floor area by a fire separation with a fire resistance rating of not more than 45 min.
d) none of the above
What would be the major occupancy classification of a 10 storey building that has on its 1st and 2nd floors retail stores and on its 3rd to 10th floors residential apartments?
a) Group E and C
b) Group E
c) Group C
d) none of the above
Please review the requirements for the following building and answer the questions below: 6 storey combustible residential building building area 1425 m2 faces 2 streets, less than 18 m in height What 3.2.2., Article would this building be classified under?
a) 3.2.2.43.
b) 3.2.2.44.
c) 3.2.2.43A.
d) 3.2.2.42.
What would be the fire resistance rating of the floor fire separations?
a) 1 hour
b) 1 ½ hours
c) 45 min.
d) none of the above
{"name":"Large Buildings 2012 BCIN Exam Free Assessment", "url":"https://www.quiz-maker.com/Q2UBIBE","txt":"Enter your email address* and click on Next to start your quiz! *Your email will not be sold, shared or used with the exception of Orderline sending you additional information on study aids and courses available to assist in your educational and career goals., Which of the following buildings is required to comply with Part 3 of Division B?, In a six storey combustible residential building, what is the required fire resistance rating of a fire separation between the residential occupancy and a restaurant with an occupant load of 56 persons?","img":"https://www.quiz-maker.com/3012/images/ogquiz.png"}
Powered by: Quiz Maker